F38 Material distributor sensor defect or door open

Possible cause:

All solenoid valves are de-energized.
The material distributor door is open.
The material distributor is not fully inserted or retracted when running the baler in its automatic mode and the door is closed.
The material distributor limit switches are defective.
This error is indicated only in automatic mode. In manual mode the baler stops without indication on the main control panel display.

Rectification:

Check the material distributor door and its limit switches.
Check the position of the material distributor and its limit switches.
Exchange any defective limit switch for an identical new item.
Moving parts. Only qualified personnel (15, 19)