F44 Bale length sensor defect

Possible cause:

This error is indicated if the main press has moved forward for at least 60 seconds but the bale length monitor gives no pulse, or if the main press makes 7 cycles without the bale length meter giving any pulse.

Rectification:

Check that the bale length monitor cogwheel is not obstructed and rotates easily. When the cogwheel is turned one snap, the bale length monitor PLC-input shall flash.
Check that the photocells are not blocked or defect. Clean or change the photocells.
Only qualified personnel (19)